with true RMS specification and CAT III 600V protection, with a black EBTN display
UT139S is a new professional multimeter with true RMS specification and CAT III 600V protection designed for the needs of electricians, with a black EBTN display. The device meets cETLus certification and includes a number of extra features such as low impedance voltage (LoZ), non-contact Voltage Measurement (NCV), capacitance measurement for capacitors, or temperature Measurement. The 31-segment analog line ensures a better display of the measured values and improved visual representation. The measuring range can be selected automatically or manually. The package includes measuring cables with tips, a thermal probe with a K-cell, and a battery.
UT139S is an ideal choice if you want a professionally equipped multimeter with a number of extra features that is also accurate, safe, easy to read and use.
Multimeter functions:
Technical parameters:
AC voltage measurement (range, resolution, accuracy):60.00 mV / 0.01 mV / ± 1.0 % + 3600.0 mV / 0.1 mV / ± 1.0 % + 36,000 V / 0.001 V / ± 0.8 % + 360.00 V / 0.01 V / ± 0.8 % + 3600.0 V / 0.1 V / ± 0.8 % + 3LPF 600.0 V / 0.1 V / ± 4.0 % + 3LoZ 600.0 V / 0.1 V / ± 2.0 % + 10
AC current measurement (range, resolution, accuracy):600.0 μA / 0.1 μA / ± 1.0 % + 36000 μA / 1 μA / ± 1.0 % + 360.00 mA / 0.01 mA / ± 1.0 % + 3600.0 mA / 0.1 mA / ± 1.0 % + 36.000 A / 0.001 A / ± 1.2 % + 310.00 A / 0.01 A / ± 1.2 % + 3
DC voltage measurement (range, resolution, accuracy):60 mV / 0.01 mV / ± 0.7 % + 3600.0 mV / 0.1 mV / ± 0.5 % + 26.000 V / 0.001 V / ± 0.7 % + 360.00 V / 0.01 V / ± 0.7 % + 3600.0 V / 0.1 V / ± 0.7 % + 3
DC current measurement (range, resolution, accuracy):600.0 μA / 0.1 μA / ± 0.7 % + 26000 μA / 1 μA / ± 0.7 % + 260.00 mA / 0.01 mA / ± 0.7 % + 2600.0 mA / 0.1 mA / ± 0.7 % + 26.000 A / 0.001 A / ± 1.0 % + 310.00 A / 0.01 A / ± 1.0 % + 3
Resistance measurement (range, resolution, accuracy):600.0 Ω / 0.1 Ω / ± 1.0 % + 26.000 kΩ / 0.001 kΩ / ± 0.8 % + 260.00 kΩ / 0.01 kΩ / ± 0.8 % + 2600.0 kΩ / 0.1 kΩ / ± 0.8 % + 26.000 MΩ / 0.001 MΩ / ± 1.2 % + 360.00 MΩ / 0.01 MΩ / ± 1.5 % + 5
Capacitance measurement (range, resolution, accuracy):9,999 nF / 0.001 nF / at REL mode ± 4 % + 1099.99 nF to 999.9 μF / 0.01 nF to 0.1 μF / ± 4 % + 109999 mF to 99.99 mF / 0.001 mF to 0.01 mF / ± 10 %
Frequency and duty cycle measurement (range, resolution, accuracy):9999 Hz to 9999 MHz / 0.001 Hz to 0.001 MHz / ± 0.1 % + 40.1 % to 99.9 % / 0.1 % / only for reference
Temperature measurement in °C (range, resolution, accuracy):- 40 to 40°C / 1°C / ± 4> 40 to 500°C / 1°C / ± 1.0 % + 4> 500 to 1000°C / 1°C / ± 2.0 % + 4
Temperature measurement in °F (range, resolution, accuracy):- 40 to 104°F / 1°F / ± 5> 104 to 932°F / 1° F / ± 1.5 % + 5> 932 to 1832°F / 1°F / ± 2.5 % + 5
With the thermostatic probe (cell type K), only temperatures up to 250°C / 482°F
Display type: LCD EBTNDisplay diagonal: 68 mmSampling frequency: 3 / sNumber of digits: 6000Analog line: 31 segmentsMultimeter dimensions: 170 x 80 x 48 mmPower supply: 2 x AA 1.5 V battery (included)Thermal probe with type K (included)Test leads with tips (included)Fuse F1: 6 x 32 mm FF 600 mA H 600 V (installed)Fuse F2: 6 x 25 mm FF 10 A H 600 V (installed)Fall resistance: 1 mWeight: approx. 354 g (including batteries)Operating temperature: - 10 to 50°C
The device meets following standards:cETLus, CAT III 600V, double insulation, overload protection 600V-PTC, pollution class IIEN 61326-1: 2013; EN 61326-2-2: 2013EN 61010-1: 2010; EN 61010-2-030: 2010; EN 61010-2-033: 2012Complies with UL STD standards: 61010-1, 61010-2-030Certified by CSA STD. C22.2 No. 61010-1, 61010-2-030, 61010-2-033